Tpo Coated Sheet Metal for PV Roofing System

Product Details
Customization: Available
Color: Gray, White, Tan, Patina Green, Rock Brown, Terra
Material: Hot Dipped Galvanized Steel (G90)+Tpo
Still deciding? Get samples of US$ 20/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Plant Area
101~500 square meters
  • Tpo Coated Sheet Metal for PV Roofing System
  • Tpo Coated Sheet Metal for PV Roofing System
  • Tpo Coated Sheet Metal for PV Roofing System
  • Tpo Coated Sheet Metal for PV Roofing System
  • Tpo Coated Sheet Metal for PV Roofing System
  • Tpo Coated Sheet Metal for PV Roofing System
Find Similar Products

Basic Info.

Steel Thickness
0.024" (0.6 mm) Nominal (24 Gauge)
Membrane Thickness
0.015′′~0.035" (0.38~0.89 mm) or Customized
Membrane Reinforced
as Your Requirements
Weight
0.937~1.1 Lb/FT2(4.6~5.4 Kg/M2)
Type
Roofing and Waterproofing
Ceiling Tile Type
Metal Ceilings
Surface Treatment
Film Coated
Function
Waterproof
Usage
Outdoor
After-sales Service
Online Technical Support
Ceiling Tile Shape
Rectangular or Customized
Transport Package
5 or 30 Sheets Per Pallet
Specification
4′ (1.21 m) x 10′ (3.05 m)
Origin
China
Production Capacity
30000 Per Month

Product Description

TPO Coated Metal Sheets for Roof

Overview&Description

EASEBASE's Flex Clad Metal uses 24 gauge, G-90 Galvanized Steel and laminates a Thermoplastic Roofing Membrane for a strong, durable product.
These products are created by laminating a layer of 15~35 mil TPO membrane onto a G90 galvanized steel sheet of 24-gauge metal. The TPO membrane allows for easy welding with the main roofing membrane, eliminating the need for separate cover strips or adhesive. The coated metal can be cut to the desired width and used to create drip edges or other roof perimeter edging profiles.
All EASEBASE TPO Coated Metal products meet stringent quality tolerances required for use in a manufacturer's warranted roofing system.

Tpo Coated Sheet Metal for PV Roofing SystemTpo Coated Sheet Metal for PV Roofing SystemTpo Coated Sheet Metal for PV Roofing SystemTpo Coated Sheet Metal for PV Roofing System

Size

 

Typical Properties and Characteristics
Sheet Size 4' (1.21 m) x 10' (3.05 m)
Steel Thickness  0.024" (0.6 mm) nominal (24 gauge)
Membrane thickness  0.015''~0.035" (0.38~0.89 mm) or customized
Membrane Reinforced as your requirements
Steel Type Hot Dipped Galvanized Steel - G90
Color Gray, White, Tan, Patina Green, Rock Brown, 
Terra Cotta, Medium Bronze, and Slate Gray 
Packaging 5 or 30 sheets per pallet
Marks Metal sheets are 
also available in aluminum, stainless, 
and 20 ga. Galvanized
Weight  0.937~1.1 lb/ft2(4.6~5.4 kg/m2)
Features and Benefit

EASEBASE TPO-Coated Metal offers an efficient roofing solution, as it allows for direct welding of the membrane to the metal, which eliminates the need for adhesive stripping. EASEBASE TPO-Coated Metal is available in multiple colors, providing both a functional and aesthetic appeal.

The EASEBASE TPO membrane may also be directly heat welded to the TPO Coated Metal, resulting in significant savings for contractors as there is no need to strip in edging with TPO Cover Strip or other flashing materials. This allows for easy installation and time efficiency, ultimately reducing costs. Easy to cut and form for creating a variety of edge sizes and profiles, EASEBASE eliminates the need for additional TPO Pressure-Sensitive Coverstrip, ensuring a seamless and professional finish across any commercial roof. Providing a monolithic, watertight protection for TPO roofing systems.

 

Applications

TPO coated metal is used on single ply roofing systems as perimeter edge metal, cap metal, and for other prefabricated accessories compatible with TPO roofing systems.

 

Installation

Install our TPO Coated Metal with a minimum 1/8-inch (3.1 mm) and maximum 1/4-inch (6.3 mm) between adjoining sections. 
Do not install in direct contact with asphalt or asphaltic membranes. If exposed to weather prior to installation, clean the membrane side of the TPO Coated Metal with an appropriate cleaner and dry thoroughly before attempting to heat weld.
1. Install 2-inch (50.8 mm) wide heat resistant tape over joints in TPO Coated Metal.
2. Heat weld a 6-inch (152.4 mm) wide piece of TPO Unsupported Flashing over the joint.
3. Machine welds to TPO Coated Metal must be at least 1 1/2-inch (38.1 mm) wide. Hand welds must be at least 2-inch (50.8 mm) wide.

 

Precautions

1.Store coated metal in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. TPO Coated Metal that has been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot-air welding.
2.Wear proper personal protective equipment, such as gloves and eye protection.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier